CONTROL SYSTEM
11-6
SM SAFRPM 1-A.0 GB
11.11.2 Positioning
The vane is once pressed to the cane stopper below to confirm the standard position and then set to
the desired angle. The positioning is decided as follows:
a. When the ON/OFF button is pressed.
b. When the vane control is change from AUTO to MANUAL.
c. When the SWING is finished.
d. When the test run starts.
e. When the power supply turns ON.
11.11.3 The auto vane changes as follows by pressing the VANE CONTROL button.
11.11.4 VANE AUTO mode
In vane auto mode, the microprocessor automatically determines the vane angle and operation
to make the optimum room-temperature distribution.
11.11.5 SWING mode
When presses the SWING button, the vane swings.
11.12 TIMER Operation
11.12.1 To activate the air conditioner at the desire time,
follow the procedure specified below(the remote control and air conditioner are switched off):
a. Press the TIMER button
b. Select the desired mode by pressing the mode button.
c. Select the desired temperature by pressing the UP/DOWN button (only possible when the ‘cool’
or ‘heat’ mode is selected).
d. Select the ventilator speed (low, medium or high) or automatic mode (only possible
when the feel, COOL or HEAT mode is selected) by pressing the Fan button. The ventilator always
operates in the auto mode when the dry mode is selected.
e. Select swing or no swing by pressing the SWING button
f. Press the TIMER button (‘h’ flashes ).
g. Use the UP/DOWN button to select the time at which the air conditioner must activate
(between 0 and 10 hours can be set at every half hour-between 10 and 24 hours can be set at every
hour).
h. Press the TIME button (‘h’ stops flashing) and the preset time appears in the display.
i. Press the TIME button again to delete the selected data from the memory.
Note: if no buttons are pressed during the programming of the timer function, thee remote control will
switch off automatically after 10 seconds.
11.12.2 To switch the air conditioner off at the desired time,
follow the procedure specified below (the remote control and air conditioner are switched off):
a. Press the timer button.
b. Use the UP/DOWN button to select the time at witch.
11.13 Emergency Operation
When the EMERGENCY operation switch is pressed once, COOLING mode is selected and if in
3 seconds the emergency operation switch is pressed again, mode is selected. Then pressed once
again, the unit is switch off.
When the remote controller is missing, has failed or the batteries run down, press the EMERGENCY
operation switch on the front of the indoor unit. The unit will start. The first 30 minutes of operation
will be the test run operation. The operation is for servicing. The indoor fan runs at high speed and