Electra GC 24 RC Instrukcja Obsługi Strona 41

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 40
PERFORMANCE DATA & PRESSURE CURVES
5-21SM SX Ser1-A.3 GB
5.16 SX 24 / OU7-24, OU7-24Z & OU7-24T R410A
5.16.1 Cooling Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
DB OU COIL (°C)
DATA
ENTERING AIR WB/DB ID COIL ( °C)
15/21 17/24 19/27 21/29 23/32
15
(1)
TC
7.20 7.46 7.63 7.81 7.93
SC
5.02 5.24 5.44 5.58 5.68
PI
1.61 1.61 1.62 1.62 1.63
20
(1)
TC
6.97 7.34 7.57 7.75 7.92
SC
4.92 5.19 5.41 5.56 5.67
PI
1.75 1.75 1.76 1.77 1.77
25
TC
6.59 7.12 7.48 7.71 7.89
SC
4.80 5.09 5.37 5.52 5.63
PI
1.89 1.90 1.91 1.93 1.94
30
TC
6.16 6.71 7.25 7.51 7.73
SC
4.65 4.94 5.25 5.40 5.51
PI
2.04 2.07
2.08
2.10 2.12
35
TC
5.71 6.19
6.83
7.17 7.51
SC
4.42 4.74 5.13 5.28 5.38
PI
2.20 2.23
2.27
2.29 2.30
40
TC
5.19 5.65
6.16
6.74 7.09
SC
4.16 4.48 4.85 5.01 5.11
PI
2.37 2.41 2.45 2.48 2.50
46
TC
4.50 4.92 5.41 5.98 6.44
SC
3.84 4.11 4.43 4.58 4.68
PI
2.59 2.63 2.69 2.73 2.76
LEGEND
TC Total Cooling Capacity, kW
SC – Sensible Capacity, kW
PI Power Input, kW
WB Wet Bulb Temp., (
o
C)
DB Dry Bulb Temp., (
o
C)
ID Indoor
OU Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient
conditions, refer to Optional Accessories (Chapter 15).
CONTENT
Przeglądanie stron 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 158 159

Komentarze do niniejszej Instrukcji

Brak uwag