Electra GC 24 RC Instrukcja Obsługi Strona 8

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 7
PRODUCT DATA SHEET
2-2 SM SX Ser1-A.3 GB
2.2 SX 12 / ONG-12 R410A
Model Indoor Unit SX-12
Model Outdoor Unit ONG-12
Installation Method of Pipe Flared
Characteristics Units Cooling Only Cooling Heating
Capacity
(1)
Btu/hr 12010 12010 12620
kW 3.52 3.52 3.7
Power input
(1)
kW 1.155 1.155 1.15
EER (Cooling) or COP(Heating)
(1)
W/W 3.05 3.05 3.22
Energy efficiency class B B C
Power supply V/Ph/Hz 220-240V/Single/50Hz
Rated current A 5.2 5.2 5.2
Starting current A 24
Circuit breaker rating A 15
INDOOR
Fan type & quantity Centrifugal x 2
Fan speeds H/M/L RPM 830/770/710
Air flow
(2)
H/M/L m3/hr 420/390/350
External static pressure Min-Max Pa 0
Sound power level
(3)
H/M/L dB(A) 56/53/51
Sound pressure level
(4)
H/M/L dB(A) 45/41/38
Moisture removal l/hr 1.5
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 820x630 x190
Weight kg 22
Package dimensions WxHxD mm 890x710x280
Packaged weight kg 26
Units per pallet units 14
Stacking height units 7 levels
OUTDOOR
Refrigerant control Capillary tube
Compressor type, model Rotary, Toshiba PA145X2C-4FT
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 810
Air flow H/L m3/hr 1850
Sound power level H/L dB(A) 62 64
Sound pressure level
(4)
H/L dB(A) 52 53
Dimensions WxHxD mm 795x610x290
Weight kg 35 36
Package dimensions WxHxD mm 945x655x395
Packaged weight kg 39 40
Units per pallet Units 9
Stacking height units 3 levels
Refrigerant type R410A
Refrigerant chargless distance kg/m 1.23kg/7.5m 1.27kg/7.5m
Additional charge per 1 meter g/m 7.5m<Lin<15m:+15g/m
Connections between units
Liquid line In.(mm) 1/4"(6.35)
Suction line In.(mm) 3/8"(9.53)
Max. tubing length m. Max.15
Max. height difference m. Max.7
Operation control type Remote control
Heating elements kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.