Electra GC 24 RC Instrukcja Obsługi Strona 53

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 52
ELECTRICAL DATA
6-1SM SX Ser1-A.3 GB
6. ELECTRICAL DATA
6.1 Single Phase Units
MODEL SX 9 SX 12 SX 15 SX 18
Power Supply
To indoor To indoor To indoor To Indoor To outdoor
1PH-230V-50Hz 1PH-230V-50Hz 1PH-230V-50Hz 1PH-230V-50Hz
Max Current, A 7.1 7.6 10.4 12
Circuit Breaker 10 16 16 16
Power Supply Wiring
No. X Cross Section mm
2
3x1.5 mm
2
3x1.5 mm
2
3x1.5 mm
2
3x2.5 mm
2
Interconnecting Cable RC Model
No. X Cross Section mm
2
5x1.5 mm
2
+2x0.5 mm
2
(OCT sensor)
5x1.5 mm
2
+2x0.5 mm
2
(OCT sensor)
5x1.5 mm
2
+2x0.5 mm
2
(OCT sensor)
5x2.5 mm
2
+2x0.5 mm
2
(OCT sensor)
6x1.5 mm
2
+2x0.5 mm
2
(OCT sensor)
Interconnecting Cable ST Model
No. X Cross Section mm
2
4x1.5 mm
2
4x1.5 mm
2
4x1.5 mm
2
4x2.5 mm 5x2.5 mm
MODEL SX 24 SX 30
Power Supply
To Outdoor
To outdoor
1PH-230V-50Hz 1PH – 230V – 50 Hz
Max Current, A
15 17
Circuit Breaker
20 25
Power Supply Wiring
No. X Cross Section mm
2
3 x 2.5 mm
2
3 x 4 mm
2
Interconnecting Cable RC Model
No. X Cross Section mm
2
6 x 1.5 mm
2
+ 2 X 0.5 mm
2
(OCT Sensor) 6 x1.5 mm
2
+2 x 0.5 mm
2
(OCT sensor)
Interconnecting Cable ST Model
No. X Cross Section mm
2
5 x 1.5 mm
2
+ 2 X 0.5 mm
2
(OCT Sensor) 5 x1.5 mm
2
(OCT Sensor)
6.2 Three Phase Units
MODEL SX 18T SX 24T SX 30T
Power Supply
To outdoor To outdoor To Outdoor
3PH-400V-50Hz 3PH – 400V – 50 Hz 3PH – 400V – 50 Hz
Max Current, A
4.2
3 x 7.5
3 x 9.2
Circuit Breaker
6
3 x 10
3 x 16
Power Supply Wiring No. X
Cross Section mm
2
5x1.5mm
2
5 x 1.5 mm
2
5 X 2.5 mm
2
Interconnecting Cable RC
Model No. X Cross Section mm
2
6x1.5 mm
2
+2x0.5 mm
2
(OCT senser)
6 X 1.5 mm
2
+ 2 X 0.5 mm
2
(OCT Sensor)
6 X 1.5 mm
2
+ 2 X 0.5 mm
2
(OCT Sensor)
Interconnecting Cable ST
Model No. X Cross Section mm
2
5x1.5 mm
2
5 X 1.5 mm
2
+ 2 X 0.5 mm
2
(OCT Sensor)
5 X 1.5 mm
2
+ 2 X 0.5 mm
2
(OCT Sensor)